Classification of Item Condition
H =
Hazardous! - Health and Safety
Caution. Issues found are health and/or safety
concerns and could become hazardous under certain
conditions. They should be immediately addressed by a qualified
technician.
S
= Serious
- Repair, Replacement,
Maintenance.
Issues found are in definite need of repair and
could develop into a hazardous condition. If not
taken care of they likely will cause more
consequential damage to
the structure and/ or endanger people. They should be addressed by a qualified
technician as soon as possible.
P =
Poor - Repair, Replacement,
Maintenance.
Issues found are in need of repair, replacement
and/or should be addressed by a qualified
technician as soon as possible.
F =
Fair - Repair, Replacement,
Maintenance. Issues found are nearing the
end of their useful life but are still functional.
G =
Good - Item in good physical condition
U = Upgrades
recommended.
Certain components or systems may not have been
available at time of construction but would improve
safety or structure. I.e. smoke detectors, gas
detectors, GFI receptacles, tempered (safety) glass,
rails, drainage, etc.
| Building Type |
Single Family Residence |
| Item: |
electrical wiring |
| Condition: |
S = serious |
| Comment: |
Code violation; Wires to be enclosed, exposed wiring is subject to external
influences and can become a fire hazard |
|
 |
| Building Type |
Single Family Residence |
| Item: |
electrical wiring |
| Condition: |
S = serious |
| Comment: |
Code violation, 30 Amp panel is feeding a 50 Amp panel, a fire waiting to
happen |
|
 |
| Building Type |
Single Family Residence |
| Item: |
electrical wiring |
| Condition: |
S = serious |
| Comment: |
Outlet scorched, indicating excessive power draw, which
may have damaged wiring inside the wall; potential fire hazard |
|
 |
| Building Type |
Single Family Residence |
| Item: |
electrical wiring |
| Condition: |
P = Poor |
| Comment: |
Code violation; Wires running through highly flammable
materials. Requires speedy attention. |
|
 |
| Building Type |
Commercial |
| Item: |
structural beam |
| Condition: |
S = serious |
| Comment: |
structural beams weakened by cut-out for pipe.
(expensive fix either requires beam enforcement or pipe
re-routing and beam replacement) |
|
 |
| Building Type |
Single Family Residence |
| Item: |
plumbing |
| Condition: |
P = Poor |
| Comment: |
unsafe & improper drain plumbing, obviously quick fix,
using wrong parts; expect drain clogging and difficult or
impossible cleanout. |
|
 |
| Building Type |
Single Family Residence (NEW) |
| Item: |
plumbing |
| Condition: |
P = Poor |
| Comment: |
unsafe & improper cold water pipe joint (quick fix),
sealed with silicone. Will fail! |
|
 |
| Building Type |
Single Family Residence |
| Item: |
structural supports |
| Condition: |
P = Poor |
| Comment: |
improper supports; correction highly recommended |
|
 |
| Building Type |
Commercial |
| Item: |
foundation |
| Condition: |
S = serious |
| Comment: |
foundation cracked; water penetration will damage/weaken
structural steel inside and lead to further structural
damages; requires speedy attention |
|
 |
| Building Type |
Commercial |
| Item: |
electrical wiring |
| Condition: |
P = Poor |
| Comment: |
Code violation; high and low voltage wires, phone and
network cables intermingled. Hazardous, immediate attention
required |
|
 |
| Building Type |
Single Family Residence (NEW) |
| Item: |
electrical wiring |
| Condition: |
H = Hazardous |
| Comment: |
Panel burned likely due to excessive power draw, FAKE
WIRING (see also below . . .) or loose connection;
CAUTION! electrical wiring exiting the top may be burnt
inside the wall for some distance. Opening of wall required
to determine end point of damage. |
|
 |
| Building Type |
GENERAL ISSUE |
| Item: |
electrical wiring |
| Condition: |
H = Hazardous ! ! ! |
| Comment: |
FAKE ELECTRICAL WIRING, likely produced in China. It is
made to look like copper wiring, but the core is aluminum
(substandard!!!). Due to expansion and contraction, wiring
connections are known to loosen over time and thereby
produce arching, leading to fires. |
|
 |
|
|